Storm line open 24/7 · (406) 555-0142

Serving the Ashford ValleyMon–Fri 07:00–18:00 · Sat 08:00–13:00

HaldenRoofing Co.
Halden roofer setting a skylight with bronze step flashing into a shingle roof

Next free inspection Tue 11:30

06 · Ventilation & skylights

A cooler attic, a drier skylight

A hot, damp attic shortens the life of any roof. We balance intake and exhaust vents, and install or reflash skylights so they stop being the first place a roof leaks.

Most jobs
$690–$2,900
On site
Half a day to 1 day
Warranty
2 years, or 25 with a new roof
Checked with
Attic temperature and moisture

(Who it is for)

Signs the attic is working against the roof

Most ventilation problems show up somewhere else first: in the shingles, in the ceilings, or as ice at the eaves.

  • Ice dams at the eaves

    Warm attic air melts snow, which refreezes at the cold overhang and backs up under the shingles.

  • Frost or rust on nail tips

    Moist house air condensing on the cold underside of the deck in winter.

  • Shingles ageing fast

    Blistering and curling years early, especially over a hot attic.

  • Musty smell or dark sheathing

    Mould on the underside of the deck, usually near bathroom fans that vent into the attic.

  • Skylight stains

    Brown rings around the shaft, or drips in heavy rain only.

  • Upstairs rooms too hot

    Heat radiating down from an unvented attic in summer.

(How it works)

Air in low, out high, in equal amounts

Cool air comes in at the soffits, sweeps the underside of the deck and leaves at the ridge, carrying heat in summer and moisture in winter.

How balanced attic ventilation works Cross-section of a gable roof. Cool outside air enters through vents in the soffits at both eaves, flows up under the roof deck through baffles above the insulation, and leaves as warm air through a continuous ridge vent at the peak. Exhaust: ridge vent warm, moist air out Intake: soffit vents cool air in Intake: soffit vents cool air in Insulation on the attic floor, baffles keep the eaves clear
Cool intake airWarm exhaust air

How much you need: the 1-in-300 rule

1 square foot (144 sq in) of net free vent area for every 300 square feet of attic floor, split half and half. Footages assume typical products: about 18 sq in per foot of ridge vent and 9 sq in per foot of continuous soffit vent. We check the maker's rating on every job.

Net free ventilation area needed by attic size
AtticNet free areaRoughly
1,000 sq ft attic floor480 sq in total · 240 in, 240 out14 ft ridge · 27 ft soffit
1,500 sq ft attic floor720 sq in total · 360 in, 360 out20 ft ridge · 40 ft soffit
2,000 sq ft attic floor960 sq in total · 480 in, 480 out27 ft ridge · 54 ft soffit
2,500 sq ft attic floor1,200 sq in total · 600 in, 600 out34 ft ridge · 67 ft soffit

(What is included)

What we do

Every job starts with the attic: temperature, moisture and a count of the vents you have.

Attic and skylightsWhat we do
  1. 01Measure the attic

    Floor area, existing vent area, temperature and moisture readings. We work out what you have against what you need.

  2. 02Intake at the soffits

    Continuous or individual soffit vents, with baffles so insulation does not block the airflow.

  3. 03Exhaust at the ridge

    Shingle-over ridge vent cut in along the ridge. We remove mixed exhaust (box vents plus ridge vent) that short-circuits the airflow.

  4. 04Bathroom and kitchen fans

    Ducted in insulated pipe out through a proper roof cap, not into the attic or the soffit.

  5. 05Skylight reflashing

    New manufacturer flashing kit and ice shield collar, with the shingles around it relaid.

  6. 06Skylight replacement or removal

    New deck-mounted unit with its own kit, or removed and decked over if you would rather not have it.

(Skylights)

Reflash, replace or remove?

A skylight is a hole in the roof with a window in it. When it leaks, the flashing is usually the cause, not the glass.

  • Unit under 15 years old, glass sound, leak at the edgesReflash

    New flashing kit and ice shield collar. From $690.

  • Glass fogged or cracked, or unit over 15–20 years oldReplace

    New deck-mounted unit with its own kit. From $1,850.

  • Roof being replaced anywayReplace

    The kit is designed to go in with the roof, not cut in later.

  • Room is bright enough without itRemove

    Removed, decked over and shingled to match. From $980.

(How it runs)

How a ventilation job runs

Usually half a day, a full day with a skylight replacement.

  1. Visit

    Attic survey

    Area measured, readings taken, photos of every vent and fan outlet.

  2. Quote

    Balanced plan

    What to add, what to close off, and the net free area before and after, in writing within 48 hours.

  3. Install

    Intake first, exhaust second

    Soffit vents and baffles, then the ridge cut and vent. Fans ducted out through the roof.

  4. Follow-up

    Readings again

    A second temperature and moisture check in the next season, sent to you with the photos.

(Price guide)

Guide prices

Including materials, labour and making good the shingles around the work.

Guide prices for ventilation & skylights
JobWhat it coversGuide price
Ridge vent conversionCut in shingle-over vent, up to 40 ft, close off old box vents$690–$1,100
Continuous soffit intakePer foot, with baffles in each rafter bay$12–$18 / ft
Bathroom fan ducted through the roofInsulated duct, new roof cap and flashing$420–$650
Skylight reflashExisting unit, new flashing kit and ice shield collar$690–$1,050
Skylight replacementDeck-mounted, fixed 2 × 4 ft unit with kit$1,850–$2,900
Remove skylight and deck overShingled to match, ceiling left ready for plaster$980–$1,500

(Questions)

Straight answers before you call

Still unsure what your roof needs?

Book a free inspection
How much ventilation does my attic need?

The usual rule is 1 square foot of net free vent area for every 300 square feet of attic floor, split evenly between intake low down and exhaust at the ridge. The table above works it through for common attic sizes.

Can I have too much ventilation?

It is rare, but mixing exhaust types (box vents plus a ridge vent, or a powered fan plus a ridge vent) can pull air from the wrong place. More exhaust than intake can also pull conditioned air from the house.

Should I replace my skylight when I replace the roof?

If the skylight is more than 15 years old, usually yes. Its flashing kit is designed to be installed with the roof, and replacing it later means cutting into new shingles.

My skylight only leaks in heavy rain. Is it the glass?

Rarely. It is usually the flashing, or condensation running off the inside of the glass. We check both before recommending anything.

(Free inspection)

Ask about your attic.

We measure what you have against what you need and send a balanced plan in writing within 48 hours.